# Liebherr alarm and power-failure diagnosis

### Seven things this make does on purpose

- The alarm sounds and the alarm icon lights — touching the icon silences it
- The door alarm sounds after about 180 seconds of an open door
- The temperature display and the alarm LED flash together when the freezer is not cold enough
- The freezer display shows two dashes until it is below freezing
- The power-failure light comes on after an outage, and will report the worst temperature reached
- The display flashes when you change a temperature, or when loading causes cold loss
- The ice-maker lamp flashes when the water tank is empty or unseated

### And one it does not explain

F1 to F5. The maker prints the number and publishes no meaning for it, asking only that you have it available when you call. We write it down and quote it; we do not pretend to decode it.

What this involves

May end in no repair at all, and we say so upfront

Every documented signal checked against the manual

The alarm history read before anything is cleared

Read what the appliance is showing, before clearing it

A number between F1 and F5, a flashing display, a lit alarm LED, a power-failure indicator. Each of these is evidence and each of them disappears when somebody presses the wrong thing first.

Check it against what the maker documents

Door open longer than 180 seconds. Temperature not low enough after warm food or a long door-open. Below-freezing-only display showing dashes. A power failure that pushed the compartment warm. All published, all normal.

Ask the appliance what it recorded

The power-failure function will show the highest temperature reached during the outage. That is a number worth having before deciding about the food.

Then decide whether there is anything to repair

And if there is not, say so, explain what happened, and charge for the visit rather than inventing work.

Seven things this make does on purpose

The alarm sounds and the alarm icon lights — touching the icon silences it

The door alarm sounds after about 180 seconds of an open door

The temperature display and the alarm LED flash together when the freezer is not cold enough

The freezer display shows two dashes until it is below freezing

The power-failure light comes on after an outage, and will report the worst temperature reached

The display flashes when you change a temperature, or when loading causes cold loss

The ice-maker lamp flashes when the water tank is empty or unseated

And one it does not explain

F1 to F5. The maker prints the number and publishes no meaning for it, asking only that you have it available when you call. We write it down and quote it; we do not pretend to decode it.

### My freezer beeps three times and stops. Is it broken?

Not necessarily, and this is one of the most common questions about this make. The audible alarms on these cabinets are documented: a door alarm after about three minutes of the door being open, and a temperature alarm when the freezer is not cold enough. Both stop on their own when the cause goes away. What is worth a call is an alarm that keeps returning with the door shut and nothing new inside.

### It alarmed after the power came back on.

That is the appliance telling you the compartment got warm while the power was off — which is exactly what you would want it to do. Touch the alarm icon to see the highest temperature it reached. No repair; a decision about the food.

### Will you charge me if nothing is wrong?

Yes, and we would rather say that now than at your door. Somebody drove to you, read the appliance and explained what it was doing. What you will not get is a part you did not need in order to make the visit feel worthwhile.

---

**[Read full article: Alarm and power-failure diagnosis](https://liebherrmiami.support/services/alarm-and-power-failure-diagnosis/)**